Co-ordinated Sciences (0654) · May/June 2022 · Question paper 53
Cambridge Co-ordinated Sciences (0654) question paper for paper 53, May/June 2022 — 0654/53/M/J/22, file 0654_s22_qp_53.pdf.
Text of this paper
Cambridge IGCSE™
* 8 3 3 4 1 7 5 8 1 5 *
CO-ORDINATED SCIENCES
0654/53
May/June 2022
Paper 5 Practical Test
2 hours
You must answer on the question paper.
You will need:
The materials and apparatus listed in the confidential instructions
INSTRUCTIONS
●
Answer all questions.
●
Use a black or dark blue pen. You may use an HB pencil for any diagrams or graphs.
●
Write your name, centre number and candidate number in the boxes at the top of the page.
●
Write your answer to each question in the space provided.
●
Do not use an erasable pen or correction fluid.
●
Do not write on any bar codes.
●
You may use a calculator.
●
You should show all your working and use appropriate units.
INFORMATION
●
The total mark for this paper is 60.
●
The number of marks for each question or part question is shown in brackets [ ].
●
Notes for use in qualitative analysis are provided in the question paper.
For Examiner’s Use
1
2
3
4
5
6
Total
This document has 20 pages. Any blank pages are indicated.
DC (KN/CGW) 303320/3
© UCLES 2022
[Turn over
2
1
Catalase is an enzyme found in living cells such as celery cells.
Catalase speeds up the breakdown of hydrogen peroxide into water and oxygen gas.
The catalase is not used up in the reaction.
You are going to investigate the volume of oxygen gas made using celery puree and hydrogen
peroxide solution.
(a) The apparatus shown in Fig. 1.1 has been set up for you.
measuring cylinder
stopper
clamp
water
boiling
tube
Fig. 1.1
Procedure
•
•
•
•
•
•
Use the stirring rod to mix the celery puree.
Remove the stopper from the boiling tube (large test-tube) and pour in about 2 cm depth
of celery puree.
Use the syringe to add 2 cm3 of hydrogen peroxide solution to the boiling tube and quickly
replace the stopper.
Immediately start the stop-watch.
Read the volume of gas in the measuring cylinder and record this value in Table 1.1 at
time = 0 minutes. If the volume is below the start of the scale, then record this value as 0.
Record in Table 1.1 the volume of gas in the measuring cylinder to the nearest 0.5 cm3
every 2 minutes for 8 minutes.
Table 1.1
time / minutes
volume of gas collected / cm3
0
2
4
6
8
[3]
(b) Suggest one source of error in the procedure and state how you can overcome this.
source of error
improvement
[2]
© UCLES 2022
0654/53/M/J/22
3
(c) A student repeats the procedure in (a) using larger amounts of celery puree and
hydrogen peroxide.
The results are shown in Table 1.2.
Table 1.2
(i)
time / minutes
volume of gas collected / cm3
0
0
5
52
10
87
15
109
20
120
25
120
On the grid, plot a graph of volume of gas collected (vertical axis) against time using the
data from Table 1.2.
[3]
(ii)
© UCLES 2022
Draw the best-fit smooth curve.
[1]
0654/53/M/J/22
[Turn over
4
(iii)
Describe the relationship between the volume of gas collected and time.
[2]
(iv)
Explain the results in Table 1.2 between 20 and 25 minutes.
[1]
[Total: 12]
© UCLES 2022
0654/53/M/J/22
5
2
You are going to investigate the nutrient content of celery and potato.
You are provided with two samples of celery puree and two samples of potato puree.
(a) Procedure
•
•
•
•
Add about 1 cm depth of biuret solution to a sample of celery puree.
Add about 1 cm depth of biuret solution to a sample of potato puree.
Add a few drops of iodine solution to the other sample of celery puree.
Add a few drops of iodine solution to the other sample of potato puree.
(i)
Complete Table 2.1 by recording the final colours observed in each sample.
Table 2.1
food sample
final colour observed
with biuret solution
final colour observed
with iodine solution
celery puree
potato puree
[4]
(ii)
State the nutrients present and the nutrients absent in each food sample.
celery:
nutrients present
nutrients absent
potato:
nutrients present
nutrients absent
[2]
(b) A student tests the celery for the presence of fats.
(i)
State the two reagents the student needs to add to the celery puree.
and [1]
(ii)
State the observation for a positive result.
[1]
[Total: 8]
© UCLES 2022
0654/53/M/J/22
[Turn over
6
3
You are going to investigate the pH of several solutions and their reactivity with sodium carbonate.
The pH scale is shown in Fig. 3.1.
pH
1
description
strongly
acidic
7
weakly
acidic
14
neutral
weakly
alkaline
strongly
alkaline
Fig. 3.1
(a) (i)
Procedure
•
•
•
Place about 1 cm depth of dilute hydrochloric acid, orange juice, salt solution,
soap solution, vinegar and limewater into separate test-tubes.
To each solution, add 4 drops of universal indicator solution.
Record in Table 3.1 the colours obtained.
Table 3.1
solution
colour in
universal indicator
pH
description
dilute hydrochloric acid
orange juice
salt solution
soap solution
vinegar
limewater
[2]
(ii)
Record in Table 3.1 the pH of each solution. Use the pH colour chart.
[2]
(iii)
Record in Table 3.1 a description of each solution. Use information from Fig. 3.1.
[2]
(b) (i)
Procedure
Step 1 Place about 3 cm depth of dilute hydrochloric acid into a clean boiling tube (large
test-tube).
Step 2 Add 2 spatula loads of sodium carbonate to the dilute hydrochloric acid,
quickly start a stop-watch and time how long it takes for the fizzing to stop.
Step 3 Record in Table 3.2 this time to the nearest second.
Repeat the procedure in (b)(i) using orange juice, salt solution, soap solution, vinegar
and limewater instead of dilute hydrochloric acid.
If the mixture fizzes but takes longer than 3 minutes to stop, then record the time as
>180 seconds.
© UCLES 2022
0654/53/M/J/22
7
If the mixture does not fizz, then record ‘no reaction’ in Table 3.2.
Table 3.2
solution
time for fizzing to stop / s
dilute hydrochloric acid
orange juice
salt solution
soap solution
vinegar
limewater
[3]
(ii)
The reaction which took the least time to finish fizzing is the fastest.
List the solutions in order of rate of reaction starting with the most reactive.
If the solutions do not react, place them together at the bottom of the list.
most reactive
least reactive
[1]
(c) Look at the pH column in Table 3.1 and the rate of reaction in (b)(ii).
Describe the relationship between pH and rate of reaction with sodium carbonate.
[2]
(d) When sodium carbonate is added to dilute hydrochloric acid, carbon dioxide gas is given off.
State the test for carbon dioxide gas. Include the observation for a positive result.
test
observation
[1]
[Total: 13]
© UCLES 2022
0654/53/M/J/22
[Turn over
8
4
Solid sodium carbonate does not decompose when it is heated.
Sodium carbonate solid dissolves in water to form sodium carbonate solution.
Sodium carbonate solution does not decompose when it is heated.
Sodium carbonate solution reacts with acid to give carbon dioxide gas.
You are going to plan an experiment to find out which sodium carbonate solution, A, B or C,
contains the most dissolved solid sodium carbonate.
You are provided with three different sodium carbonate solutions, A, B and C.
You may use any common laboratory apparatus.
You are not required to do this experiment.
Include in your plan:
•
•
•
•
•
the apparatus needed
a brief description of the method, explaining any safety precautions
the measurements you will make including how to make them as accurate as possible
the variables you will control
how you will process your results to draw a conclusion.
You may include a labelled diagram if you wish.
You may include a results table if you wish. You are not required to include any results.
© UCLES 2022
0654/53/M/J/22
9
[7]
© UCLES 2022
0654/53/M/J/22
[Turn over
10
5
You are going to investigate the oscillations of a pendulum.
A pendulum has been set up in a clamp for you as shown in Fig. 5.1.
clamp
l
bob
bench
Fig. 5.1
The length l of the pendulum is the distance from the bottom of the clamp to the centre of the
pendulum bob.
(a) Measure the length l of the pendulum in centimetres to the nearest 0.1 centimetre.
l = cm [1]
(b) One complete oscillation of the pendulum is shown in Fig. 5.2.
one complete oscillation takes place when the bob swings
from X to Y and then back to X
X
Y
Fig. 5.2
(i)
Procedure
•
•
•
Give the bob a small sideways displacement.
Release it so that it swings to and fro.
Measure the time t for 20 complete oscillations.
t = s [1]
(ii)
Calculate the time T for one complete oscillation of the pendulum.
Use the equation shown.
t
T = 20
T = s [1]
© UCLES 2022
0654/53/M/J/22
11
(iii)
Calculate T2.
T2 = s2 [1]
(c) (i)
The length l in centimetres of a pendulum which has a time T for one oscillation is
calculated using the equation shown.
l = 25.0 T2
Use this equation and your value of T2 from (b)(iii) to calculate a value for l.
Give your answer to three significant figures.
l = cm [2]
(ii)
Two values are considered to be equal within the limits of experimental error if they are
within 10% of each other.
Compare your measured value of l from (a) with the calculated value of l from (c)(i).
State if your values agree within the limits of experimental error.
Justify your answer with reference to your values.
[1]
(d) Adjust the string until the length l of the pendulum is double the length you measured in (a).
Repeat the procedure in (b)(i) and the calculation in (b)(ii) for the new pendulum length.
t = s
T = s
[1]
(e) A student states that the time T for one oscillation of a pendulum is proportional to the length l
of the pendulum.
Compare your answers in (b)(ii) and (d) to state if you agree with the student.
Give a reason for your answer.
statement
reason
[1]
© UCLES 2022
0654/53/M/J/22
[Turn over
12
(f)
(i)
State one precaution you take while doing your experiment to get accurate readings.
[1]
(ii)
Human reaction timing errors occur when a stop-watch is used.
Suggest why the time t recorded for 20 oscillations of the pendulum in (d) is more
accurate than the time t for 20 oscillations of the pendulum in (b)(i).
[1]
[Total: 11]
© UCLES 2022
0654/53/M/J/22
13
BLANK PAGE
© UCLES 2022
0654/53/M/J/22
[Turn over
14
6
You are going to investigate the temperature of the air at different distances from a lamp.
The apparatus shown in Fig. 6.1 has been set up for you.
Do not move the lamp or the rule.
stand
metre rule
lamp
0
bench
Fig. 6.1
(a) Use the thermometer to measure room temperature θR to the nearest 0.5 °C.
θR = °C [1]
(b) Procedure
•
•
•
Switch on the lamp.
Place the thermometer bulb a horizontal distance dH = 10 mm from the lamp as shown in
Fig. 6.2.
Wait for approximately 20 seconds.
thermometer
stand
metre rule
lamp
bench
dH
Fig. 6.2
© UCLES 2022
0654/53/M/J/22
15
(i)
Record in Table 6.1 the temperature θH shown by the thermometer.
Table 6.1
dH / mm
θH / °C
10
20
40
60
80
100
[1]
(ii)
Move the thermometer until its bulb is a horizontal distance of dH = 20 mm from the lamp.
Record in Table 6.1 the temperature θH shown by the thermometer.
(iii)
[1]
Repeat (b)(ii) for values of dH = 40 mm, 60 mm, 80 mm and 100 mm from the lamp.
Switch off the lamp.
[1]
(c) State the relationship between the air temperature θH and the horizontal distance dH of the
thermometer bulb away from the lamp.
[1]
(d) Predict the temperature reading θ when the thermometer is at a horizontal distance of
2000 mm from the lamp.
θ = °C [1]
© UCLES 2022
0654/53/M/J/22
[Turn over
16
(e) (i)
Adjust the position of the thermometer in the clamp until its bulb is a vertical distance
dV = 100 mm above the lamp, as shown in Fig. 6.3.
stand
thermometer
dV
bench
lamp
Fig. 6.3
Record the temperature θV shown by the thermometer.
θV = °C [1]
(ii)
Calculate the difference in temperature between θV and the thermometer reading θH at a
horizontal distance of 100 mm from the lamp.
difference in temperature = °C [1]
(f)
Explain why it is important to wait for 20 seconds before reading the thermometer in (b).
[1]
[Total: 9]
© UCLES 2022
0654/53/M/J/22
17
BLANK PAGE
© UCLES 2022
0654/53/M/J/22
18
BLANK PAGE
© UCLES 2022
0654/53/M/J/22
19
BLANK PAGE
© UCLES 2022
0654/53/M/J/22
20
NOTES FOR USE IN QUALITATIVE ANALYSIS
Tests for anions
anion
test
test result
carbonate (CO32–)
add dilute acid
effervescence, carbon dioxide
produced
chloride (Cl –)
[in solution]
acidify with dilute nitric acid, then
add aqueous silver nitrate
white ppt.
bromide (Br –)
[in solution]
acidify with dilute nitric acid, then
add aqueous silver nitrate
cream ppt.
nitrate (NO3–)
[in solution]
add aqueous sodium hydroxide, then
aluminium foil; warm carefully
ammonia produced
sulfate (SO42–)
[in solution]
acidify, then add aqueous barium
nitrate
white ppt.
Tests for aqueous cations
cation
effect of aqueous sodium hydroxide
ammonium (NH4+)
ammonia produced on warming
calcium (Ca2+)
white ppt., insoluble in excess
no ppt., or very slight white ppt.
copper(II) (Cu2+)
light blue ppt., insoluble in excess
light blue ppt., soluble in excess,
giving a dark blue solution
iron(II) (Fe2+)
green ppt., insoluble in excess
green ppt., insoluble in excess
iron(III) (Fe3+)
red-brown ppt., insoluble in excess
red-brown ppt., insoluble in excess
zinc (Zn2+)
white ppt., soluble in excess, giving a
colourless solution
white ppt., soluble in excess, giving a
colourless solution
Tests for gases
effect of aqueous ammonia
–
Flame tests for metal ions
gas
test and test result
metal ion
flame colour
ammonia (NH3)
turns damp red litmus paper blue
lithium (Li+)
red
carbon dioxide (CO2)
turns limewater milky
sodium (Na+)
yellow
chlorine (Cl 2)
bleaches damp litmus paper
potassium (K+)
lilac
hydrogen (H2)
‘pops’ with a lighted splint
copper(II) (Cu2+)
blue-green
oxygen (O2)
relights a glowing splint
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
Local Examinations Syndicate (UCLES), which is a department of the University of Cambridge.
© UCLES 2022
0654/53/M/J/22