Co-ordinated Sciences (0654) · Feb/March 2024 · Question paper 52
Cambridge Co-ordinated Sciences (0654) question paper for paper 52, Feb/March 2024 — 0654/52/F/M/24, file 0654_m24_qp_52.pdf.
Text of this paper
Cambridge IGCSE™
* 2 8 8 3 8 2 2 3 7 3 *
CO-ORDINATED SCIENCES
0654/52
February/March 2024
Paper 5 Practical Test
2 hours
You must answer on the question paper.
You will need:
The materials and apparatus listed in the confidential instructions
INSTRUCTIONS
●
Answer all questions.
●
Use a black or dark blue pen. You may use an HB pencil for any diagrams or graphs.
●
Write your name, centre number and candidate number in the boxes at the top of the page.
●
Write your answer to each question in the space provided.
●
Do not use an erasable pen or correction fluid.
●
Do not write on any bar codes.
●
You may use a calculator.
●
You should show all your working and use appropriate units.
INFORMATION
●
The total mark for this paper is 60.
●
The number of marks for each question or part question is shown in
brackets [ ].
●
Notes for use in qualitative analysis are provided in the question paper.
For Examiner’s Use
1
2
3
4
5
6
Total
This document has 20 pages. Any blank pages are indicated.
DC (LK/CT) 329434/4
© UCLES 2024
[Turn over
2
1
You are going to investigate the effect of catalase on the breakdown of hydrogen peroxide.
Catalase is an enzyme found in living cells such as potato cells.
Catalase speeds up the breakdown of hydrogen peroxide into oxygen gas and water.
hydrogen peroxide
oxygen + water
You are provided with some potato puree and some hydrogen peroxide solution.
(a) (i)
Fig. 1.1 shows the assembled apparatus.
delivery tube
measuring cylinder
stopper
water
boiling tube
Fig. 1.1
Procedure
•
•
•
Use the stirring rod to mix the potato puree.
Remove the stopper from the boiling tube and add about 2 cm depth of potato puree.
Use the syringe to add 2 cm3 of hydrogen peroxide solution to the boiling tube and
quickly replace the stopper.
Immediately start the stop-watch.
Record in Table 1.1 the total volume of gas collected in the measuring cylinder
every minute for 6 minutes. Record your values to the nearest 0.5 cm3.
•
•
Table 1.1
time / min
total volume of gas
collected / cm3
volume of gas collected in each
interval of 1 minute / cm3
0
0
0
1
2
3
4
5
6
[4]
© UCLES 2024
0654/52/F/M/24
3
(ii)
Calculate the volume of gas collected in each interval of 1 minute.
Use the equations shown.
The value for 1 minute = total volume at 1 minute – the total volume at 0 minutes.
The value for 2 minutes = total volume at 2 minutes – the total volume at 1 minute.
The remaining values are calculated similarly.
Record your values in Table 1.1.
[2]
(b) A student suggests that the volume of gas collected in the final interval of 1 minute is less
than the volume of gas collected in the first interval of 1 minute.
(i)
Explain why the student expects the volume of gas collected in each 1 minute interval to
decrease during the experiment.
[1]
(ii)
State if your results support the student’s suggestion.
Use values from Table 1.1 to explain your answer.
statement
explanation
[1]
(c) Explain why repeating the procedure increases confidence in the results.
[1]
© UCLES 2024
0654/52/F/M/24
[Turn over
4
(d) Suggest one source of error in the procedure.
State how to overcome this error.
error
statement
[2]
(e) Put about 1 cm depth of hydrogen peroxide solution into a clean test-tube.
Add a few drops of universal indicator solution to this test-tube.
State the colour observed.
Determine the pH of the hydrogen peroxide solution using the colour chart.
Use the pH to describe the nature of the hydrogen peroxide solution.
colour
pH
description
[2]
[Total: 13]
© UCLES 2024
0654/52/F/M/24
5
BLANK PAGE
© UCLES 2024
0654/52/F/M/24
[Turn over
6
2
Fertilisers contain nutrients that are added to crops to help them grow.
A farmer has a choice of three fertilisers, A, B and C for use on his rice crop.
Plan an investigation to find out which fertiliser produces the highest rate of growth of the rice
plants.
You are provided with:
•
•
rice plant seedlings
fertilisers A, B and C.
You may also use any common laboratory apparatus.
You are not required to do this investigation.
Include in your plan:
•
•
•
•
•
the apparatus needed
a brief description of the method
the measurements you will make
the variables you will control
how you will process your results to draw a conclusion.
You may include a results table if you wish, you are not required to enter any readings in the table.
You may include a labelled diagram if you wish.
© UCLES 2024
0654/52/F/M/24
7
[7]
© UCLES 2024
0654/52/F/M/24
[Turn over
8
3
You are going to investigate which metal ions catalyse a reaction.
When aqueous sodium thiosulfate reacts with aqueous iron(III) nitrate the reaction mixture
immediately turns a dark brown-purple colour.
The colour of this mixture slowly fades.
A catalyst will make the brown-purple colour fade more quickly.
Fig. 3.1 shows the experiment.
aqueous sodium thiosulfate and
aqueous iron(III) nitrate
cross on a piece of white paper
Fig. 3.1
When the brown-purple colour fades it is possible to see the cross through the reaction mixture.
The time for the cross to become visible is measured.
(a) (i)
© UCLES 2024
Procedure
Using the measuring cylinder labelled
sodium thiosulfate into a clean conical flask.
Step 2
Place the conical flask over the cross on the piece of paper.
Step 3
Using a clean dropping pipette add only 1 drop of distilled water to the
conical flask.
Step 4
Using the measuring cylinder labelled I measure 20 cm3 of aqueous
iron(III) nitrate.
Step 5
Add the aqueous iron(III) nitrate to the conical flask, immediately swirl the flask
and start the stop-watch.
Step 6
Look through the mixture and when the cross becomes visible stop the
stop-watch.
Step 7
Record in Table 3.1 the time taken to the nearest second.
0654/52/F/M/24
S,
20 cm3
Step 1
add
of
aqueous
[1]
9
Table 3.1
aqueous solution
added in Step 3
time taken for the cross
to become visible / s
rate of reaction
per 100 s
distilled water
copper(II) ions
iron(II) ions
sodium ions
zinc ions
(ii)
(b) (i)
Repeat the procedure in (a)(i) four times. Each repeat has one drop of a different solution
added in Step 3 as shown in Table 3.1.
[4]
Calculate the rate of each reaction.
Use the equation shown.
rate of reaction =
100
time taken
Record in Table 3.1 your values to two significant figures.
(ii)
[2]
Distilled water is not a catalyst for this reaction.
The experiment with distilled water is a control for the investigation.
Explain why a control is used.
[1]
(iii)
Use the values in Table 3.1 to place the aqueous copper(II) ions, aqueous iron(II) ions,
aqueous sodium ions and aqueous zinc ions in order of the rates of reaction.
highest rate (best catalyst)
lowest rate
(c) (i)
[1]
Repeat the procedure in (a)(i) but in Step 3 add 5 drops of aqueous copper(II) ions
instead of one drop of distilled water.
Record the time taken for the cross to become visible.
time = s [1]
© UCLES 2024
0654/52/F/M/24
[Turn over
10
(ii)
Suggest why 5 drops of each solution are not used in the procedure in (a)(i).
[1]
[Total: 11]
© UCLES 2024
0654/52/F/M/24
11
4
You are going to identify two aqueous solutions, J and K.
(a) Procedure
•
•
•
•
•
Add approximately 1 cm depth of aqueous J into each of three test-tubes.
Complete the tests detailed in Table 4.1.
Record your observations in Table 4.1.
Repeat the tests using aqueous K instead of aqueous J.
Record your observations in Table 4.1.
Table 4.1
test
observations
aqueous J
aqueous K
add a few drops of
aqueous ammonia
add excess aqueous
ammonia
add 1 cm depth of dilute
nitric acid followed by a
few drops of aqueous
silver nitrate
add 1 cm depth of dilute
nitric acid followed by
1 cm depth of aqueous
barium nitrate
[7]
(b) State the identity of aqueous J and aqueous K.
aqueous J
aqueous K
[2]
[Total: 9]
© UCLES 2024
0654/52/F/M/24
[Turn over
12
5
You are going to measure the focal length f of a converging lens.
The equipment is assembled as shown in Fig. 5.1.
illuminated
object
converging lens in holder
u
screen
v
Fig. 5.1
(a) (i)
Procedure
•
•
•
•
Switch on the lamp.
Place the lens a distance u = 20.0 cm from the illuminated object. The illuminated
object is the triangular hole in the card.
Adjust the position of the screen until a sharp image of the illuminated object is
formed on the screen.
Record in Table 5.1 the image distance v from the screen to the lens to the nearest
0.1 cm.
Table 5.1
object distance u
/ cm
image distance v
/ cm
magnification m
20.0
30.0
40.0
50.0
60.0
[1]
(ii)
Calculate the magnification m of the image.
Use the equation shown.
m=
image distance
object distance
Record m to one decimal place in Table 5.1.
© UCLES 2024
0654/52/F/M/24
[1]
13
(b) Fig. 5.2 shows the illuminated object.
In the blank space on the right-hand side of the illuminated object, draw a diagram of the
image seen on the screen.
illuminated object
Fig. 5.2
[2]
(c) Repeat the procedure in (a) for values of u = 30.0 cm, 40.0 cm, 50.0 cm, and 60.0 cm.
(d) (i)
[2]
On the grid, plot a graph of v (vertical axis) against m.
[3]
(ii)
© UCLES 2024
Draw the best-fit straight line.
[1]
0654/52/F/M/24
[Turn over
14
(iii)
The gradient of the line is equal to the focal length f of the lens.
Calculate the gradient of your line.
Show on your graph the values you choose to calculate the gradient.
f = [2]
(e) When measuring u and v, it is important to avoid line-of-sight (parallax) errors.
Describe how to avoid such errors.
[1]
[Total: 13]
© UCLES 2024
0654/52/F/M/24
15
BLANK PAGE
© UCLES 2024
0654/52/F/M/24
[Turn over
16
6
You are going to investigate the stretching of a spring.
The spring and the metre ruler have been assembled for you as shown in Fig. 6.1.
Do not remove the spring from the clamp. Do not adjust the height of the clamps.
metre ruler
clamp
clamp
spring
stand
stand
bench
Fig. 6.1
(a) (i)
Take the reading r on the metre ruler at the bottom of the spring.
Use the set-square to make this reading accurate.
Record in Table 6.1 the reading r to the nearest 0.1 cm for mass m = 0 g.
Table 6.1
mass m
/g
0
100
200
400
reading r
/ cm
[1]
(ii)
Draw a diagram to show how you use the set-square to take an accurate reading.
[1]
© UCLES 2024
0654/52/F/M/24
17
(b) Procedure
•
•
Suspend a mass m = 100 g from the spring.
Record in Table 6.1 the reading r at the bottom of the spring.
Repeat this procedure for masses m = 200 g and 400 g.
[2]
(c) A student suggests that the reading r on the metre ruler is directly proportional to the mass m.
State if your readings support this suggestion.
Use values from Table 6.1 to justify your answer.
statement
justification
[1]
(d) Procedure
•
•
Remove the 400 g mass from the spring.
Suspend the load L from the spring.
(i)
Record the reading r at the bottom of the spring to the nearest 0.1 cm.
r = cm [1]
(ii)
Use your answer to (d)(i) and the readings in Table 6.1 to predict the mass M of
the load L.
M = g [1]
[Total: 7]
© UCLES 2024
0654/52/F/M/24
18
BLANK PAGE
© UCLES 2024
0654/52/F/M/24
19
BLANK PAGE
© UCLES 2024
0654/52/F/M/24
20
NOTES FOR USE IN QUALITATIVE ANALYSIS
Tests for anions
anion
test
test result
carbonate (CO32–)
add dilute acid
effervescence, carbon dioxide
produced
chloride (Cl –)
[in solution]
bromide (Br–)
acidify with dilute nitric acid, then
add aqueous silver nitrate
white ppt.
[in solution]
acidify with dilute nitric acid, then
add aqueous silver nitrate
cream ppt.
nitrate (NO3–)
[in solution]
add aqueous sodium hydroxide, then
aluminium foil; warm carefully
ammonia produced
sulfate (SO42–)
[in solution]
acidify, then add aqueous barium
nitrate
white ppt.
Tests for aqueous cations
cation
effect of aqueous sodium hydroxide
ammonium (NH4+)
ammonia produced on warming
calcium (Ca2+)
white ppt., insoluble in excess
no ppt., or very slight white ppt.
copper(II) (Cu2+)
light blue ppt., insoluble in excess
light blue ppt., soluble in excess,
giving a dark blue solution
iron(II) (Fe2+)
green ppt., insoluble in excess
green ppt., insoluble in excess
iron(III) (Fe3+)
red-brown ppt., insoluble in excess
red-brown ppt., insoluble in excess
zinc (Zn2+)
white ppt., soluble in excess, giving a
colourless solution
white ppt., soluble in excess, giving a
colourless solution
Tests for gases
effect of aqueous ammonia
–
Flame tests for metal ions
gas
test and test result
metal ion
flame colour
ammonia (NH3)
turns damp, red litmus paper blue
lithium (Li+)
red
carbon dioxide (CO2)
turns limewater milky
sodium (Na+)
yellow
chlorine (Cl 2)
bleaches damp litmus paper
potassium (K+)
lilac
hydrogen (H2)
‘pops’ with a lighted splint
copper(II) (Cu2+) blue-green
oxygen (O2)
relights a glowing splint
Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
Local Examinations Syndicate (UCLES), which is a department of the University of Cambridge.
© UCLES 2024
0654/52/F/M/24