*0467532656*

COMBINED SCIENCE

0653/52
May/June 2014

Paper 5 Practical Test

1 hour 30 minutes
Candidates answer on the Question Paper.
Additional Materials:

As listed in the Confidential Instructions.

READ THESE INSTRUCTIONS FIRST
Write your Centre number, candidate number and name on all the work you hand in.
Write in dark blue or black pen.
You may use an HB pencil for any diagrams or graphs.
Do not use staples, paper clips, glue or correction fluid.
DO NOT WRITE IN ANY BARCODES.
Answer all questions.
Electronic calculators may be used.
You may lose marks if you do not show your working or if you do not use appropriate units.
Notes for Use in Qualitative Analysis for this paper are printed on page 8.
At the end of the examination, fasten all your work securely together.
The number of marks is given in brackets [ ] at the end of each question or part question.

For Examiner's Use
1
2
3
Total

This document consists of 8 printed pages.
IB14 06_0653_52/2RP
© UCLES 2014

[Turn over

2
1

www.dynamicpapers.com

You will be investigating the rate at which acid moves from an aqueous solution into a block of
agar. The agar contains the indicator phenolphthalein. This indicator is purple in a pH of greater
than 8 and colourless in a pH of less than 8.
You are provided with a dish containing two agar blocks of dimensions 2 cm × 2 cm × 2 cm.
•

Use the forceps to place one, uncut, agar block into a beaker. Label this beaker A.

•

Cut the other block as shown in Fig. 1.1 to make a cube of 1 cm × 1 cm × 1 cm.
1 cm

2 cm

1 cm
2 cm

1 cm

2 cm
cut 1

2 cm

cut 2
2 cm

2 cm
1 cm

block at start

cut 3

1 cm
1 cm
block for
beaker B

Fig. 1.1
•

Return the excess agar to the dish.

•

Use the forceps to place the 1 cm × 1 cm × 1 cm block of agar into a beaker. Label this
beaker B.

(a) State the colour of the agar and what this tells you about its pH.
[1]
(b) (i) Read part (b)(ii) on page 3.
Draw a table of results to record the observations that you make in the space below.

[2]

© UCLES 2014

0653/52/M/J/14

www.dynamicpapers.com
3
(ii) •

To beaker A add sufficient hydrochloric acid to cover the block of agar and
immediately start the stopclock.

•

Record the time taken (in seconds), in your table, for the block to go colourless.

•

Repeat the procedure for beaker B containing the smaller block of agar.
[2]

(c) Explain why the agar changes colour.

[1]

(d) Identify one inaccuracy of this experimental method and suggest an improvement to reduce
this inaccuracy.
inaccuracy

improvement

[2]

(e) (i) Explain the difference between the times taken for the two blocks to go colourless in
beakers A and B.

[1]
(ii) Suggest how you could extend this experiment to be more confident about your
explanation in (i).

[1]

© UCLES 2014

0653/52/M/J/14

[Turn over

www.dynamicpapers.com
4
2

Solid X is a mixture of two salts which have the same anion. You are going to carry out a series
of tests to identify the anion and the two cations.
(a) Identification of the anion
(i) Dissolve one spatula load of solid X in a test-tube which is three-quarters full of distilled
water. Divide the resulting solution into two test-tubes in equal portions.
Record the colour of the solution.
colour of solution

[1]

(ii) To one portion of the solution add a few drops of silver nitrate solution.
Record your observations and state what you can conclude about the anion in X.
observations
conclusion about the anion

[2]

(iii) To the other portion of the solution add barium chloride solution.
Record your observations and state what you can conclude about the anion in X.
observations
conclusion about the anion

[2]

(b) Identification of the two cations
Fill a test-tube with distilled water and then empty it into a small beaker. Add one spatula
load of solid X to the water in the beaker and stir well to dissolve the solid. Do not shake.
(i) Slowly add approximately 50 cm3 of ammonia solution to the solution in the beaker.
Record your observations. Keep the mixture for (b)(ii).
observations
[1]

© UCLES 2014

0653/52/M/J/14

www.dynamicpapers.com
5
(ii) Filter the mixture from (b)(i) into a large test-tube. When you have collected about 5 cm3
of the filtrate remove the test-tube. You do not need to filter any more of the mixture.
Wash the residue with a small amount of distilled water and discard the liquid into the
beaker labelled washings.
Describe the colours of the filtrate and of the residue.
colour of filtrate
colour of residue

[2]

(iii) Use your results from (b)(i) and (b)(ii) to identify the cations in the filtrate and in the
residue.
cation in filtrate
cation in residue

© UCLES 2014

[2]

0653/52/M/J/14

[Turn over

www.dynamicpapers.com
6
3

You are going to find out how the potential difference (p.d.) across a lamp and the power of the
lamp vary with the length of resistance wire in series with the lamp.
The circuit shown in Fig. 3.1 has been set up for you.
resistance wire
l

metre rule

P

Q
C

0

sliding contact

100

A
power
source

V

switch

Fig. 3.1
(a) (i) Close the switch and place the sliding contact C on the resistance wire at a distance of
10.0 cm from end P.
Record this length l of resistance wire used, in Table 3.1.
Record, in Table 3.1, the current I flowing through the lamp and the potential
difference V across it.
Switch off the circuit.

[2]

(ii) Insert the unit for the current I in Table 3.1.

[1]

Table 3.1
length l / cm

p.d. V / V

current I /

power P / W

(iii) Repeat step (i) for values of l of 20.0 cm, 40.0 cm, 60.0 cm and 80.0 cm.
Record your values of l, I and V in Table 3.1. Remember to switch off the circuit
between readings.
[4]

© UCLES 2014

0653/52/M/J/14

7

www.dynamicpapers.com

(b) (i) Calculate the power, P of the lamp for each length of wire, using the equation
P=V×I
Record your values of P in Table 3.1 to an appropriate number of significant figures.

[2]

(ii) What have you observed, when carrying out this experiment, which shows that the
power of the lamp decreases as the length of resistance wire increases?

[1]

© UCLES 2014

0653/52/M/J/14

www.dynamicpapers.com

8

NOTES FOR QUALITATIVE ANALYSIS
Test for anions
anion

test

test result

carbonate (CO32-)

add dilute acid

effervescence, carbon dioxide
produced

chloride (Cl -)
[in solution]

acidify with dilute nitric acid, then
add aqueous silver nitrate

white ppt.

nitrate (NO3-)
[in solution]

add aqueous sodium hydroxide
then aluminium foil; warm carefully

ammonia produced

sulfate (SO42-)
[in solution]

acidify then add aqueous barium
chloride or aqueous barium nitrate

white ppt.

cation

effect of aqueous sodium hydroxide

effect of aqueous ammonia

ammonium (NH4+)

ammonia produced on warming

-

copper(II) (Cu2+)

light blue ppt., insoluble in excess

light blue ppt., soluble in excess
giving a dark blue solution

iron(II) (Fe2+)

green ppt., insoluble in excess

green ppt., insoluble in excess

iron(III) (Fe3+)

red-brown ppt., insoluble in excess

red-brown ppt., insoluble in excess

zinc (Zn2+)

white ppt., soluble in excess giving
a colourless solution

white ppt., soluble in excess giving
a colourless solution

Test for aqueous cations

Test for gases
gas

test and test results

ammonia (NH3)

turns damp red litmus paper blue

carbon dioxide (CO2)

turns limewater milky

chlorine (Cl2)

bleaches damp litmus paper

hydrogen (H2)

“pops” with a lighted splint

oxygen (O2)

relights a glowing splint

Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
Cambridge International Examinations is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of University of Cambridge Local
Examinations Syndicate (UCLES), which is itself a department of the University of Cambridge.

© UCLES 2014

0653/52/M/J/14

Advertisement