Combined Science (0653) · May/June 2014 · Question paper 51

Cambridge Combined Science (0653) question paper for paper 51, May/June 2014 — 0653/51/M/J/14, file 0653_s14_qp_51.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

Cambridge International Examinations
Cambridge International General Certificate of Secondary Education

*2665204240*

COMBINED SCIENCE

0653/51
May/June 2014

Paper 5 Practical Test

1 hour 30 minutes
Candidates answer on the Question Paper.
Additional Materials:

As listed in the Confidential Instructions.

READ THESE INSTRUCTIONS FIRST
Write your Centre number, candidate number and name on all the work you hand in.
Write in dark blue or black pen.
You may use an HB pencil for any diagrams or graphs.
Do not use staples, paper clips, glue or correction fluid.
DO NOT WRITE IN ANY BARCODES.
Answer all questions.
Electronic calculators may be used.
You may lose marks if you do not show your working or if you do not use appropriate units.
Notes for Use in Qualitative Analysis for this paper are printed on page 12.
At the end of the examination, fasten all your work securely together.
The number of marks is given in brackets [ ] at the end of each question or part question.

For Examiner's Use
1
2
3
Total

This document consists of 11 printed pages and 1 blank page.
IB14 06_0653_51/3RP
© UCLES 2014

[Turn over

www.dynamicpapers.com
2
1

You will be investigating the vitamin C content of a fruit juice.
DCPIP is a dark blue chemical that is decolourised by vitamin C. A solution containing a higher
concentration of vitamin C will take fewer drops to decolourise DCPIP.
You are provided with a set of different concentrations of vitamin C and a fruit juice of an
unknown vitamin C concentration.
(a) •

Using a dropping pipette, place two drops of DCPIP into each of five wells of a white
spotting tile.

•

Start with the 1.00% solution of vitamin C. Use a clean dropping pipette to carefully add
drops to one of the wells with the DCPIP and count how many drops are needed to
decolourise it. Immediately record your result in Table 1.1.

•

Repeat with the other solutions of different concentrations of vitamin C and then the fruit
juice, using a clean dropping pipette each time.

•

If a solution of vitamin C does not decolourise, stop when the well is full, record the
number of drops and write maximum next to it.

•

You should ignore any colour changes seen 5 minutes after adding the vitamin C to the
DCPIP.
Table 1.1
concentration of vitamin C (%)

number of drops needed to decolourise DCPIP

1.00
0.75
0.50
0.25
fruit juice
[4]

© UCLES 2014

0653/51/M/J/14

www.dynamicpapers.com
3
(b) Plot a graph on the grid below of the number of drops needed to decolourise DCPIP against
vitamin C concentration. Draw the best fit straight line.

vitamin C concentration (%)
[3]

(c) Use your graph to estimate the vitamin C concentration of the fruit juice and mark on the
graph how you worked this out.
vitamin C concentration =

%

[2]

(d) Suggest one change to the experimental method which will improve the accuracy.

[1]

© UCLES 2014

0653/51/M/J/14

[Turn over

www.dynamicpapers.com
4
2

You are going to investigate some reactions of sodium hydrogencarbonate, NaHCO3 and sodium
carbonate, Na2CO3. In parts (b) and (c) you will carry out the same tests on these two
substances. Be careful that you do not confuse the two white powders.
(a) Remove the stopper from the hard glass test-tube which is one-quarter full of solid
sodium hydrogencarbonate and attach a delivery tube.
One-quarter fill a test-tube with limewater and place the other end of the delivery tube into
the limewater. See Fig. 2.1.

heat

sodium
hydrogencarbonate

limewater

Fig. 2.1
Heat the hard glass test-tube containing the solid for at least two minutes after the limewater
has returned to a colourless solution.
Immediately remove the delivery tube from the limewater, to avoid suck back.
Record your observations including what happened to the solid and to the limewater.
Keep the solid contents of the hard glass test-tube for (d)(ii).
observations

[2]

© UCLES 2014

0653/51/M/J/14

www.dynamicpapers.com
5
(b) Place one spatula load of sodium hydrogencarbonate into a clean test-tube and add
distilled water until three-quarters full. Place the stopper in the test-tube and shake until the
solid is dissolved.
Use this sodium hydrogencarbonate solution for tests (b)(i) to (b)(iii).
(i) Place 1 cm3 of sodium hydrogencarbonate solution into a clean test-tube and add a few
drops of Universal (full range) Indicator solution.
Record the colour change.
colour change

to

[1]

(ii) Place another 1 cm3 of sodium hydrogencarbonate solution into a clean test-tube and
add an equal volume of dilute hydrochloric acid.
Record your observations.
observations
[1]
(iii) Place 2 cm3 of sodium hydrogencarbonate solution into a clean test-tube and add an
equal volume of copper sulfate solution.
Record your observations.
observations
[1]

© UCLES 2014

0653/51/M/J/14

[Turn over

www.dynamicpapers.com
6
(c) Thoroughly wash out the test-tubes used in (b)(i) to (iii).
Do NOT wash out the hard glass test-tube from (a) which is needed for (d)(ii).
Place one spatula load of sodium carbonate into a clean test-tube and add distilled water,
until three-quarters full. Place the stopper in the test-tube and shake until the solid is
dissolved. It does not matter if a small amount of solid will not dissolve.
Use this sodium carbonate solution for tests (c)(i) to (c)(iii).
(i) Place 1 cm3 of sodium carbonate solution into a clean test-tube and add a few drops of
Universal (full range) Indicator solution.
Record the colour change.
colour change

to

[1]

(ii) Place 1 cm3 of sodium carbonate solution into a clean test-tube and add an equal volume
of dilute hydrochloric acid.
Record your observations.
observations
[1]
(iii) Place 2 cm3 of sodium carbonate solution into a clean test-tube and add an equal volume
of copper sulfate solution.
Record your observations.
observations
[1]

(d) (i) Look at your results for (b) and (c) and suggest which two tests could be used to
distinguish between sodium hydrogencarbonate and sodium carbonate.
test 1
test 2

[1]

(ii) Now dissolve a spatula load of the solid remaining in the hard glass test-tube from (a) in
distilled water in a clean test-tube.
Use portions of this solution to carry out one of the two tests you have chosen in (d)(i).
Record the test used and your observations below.
test used
observation

© UCLES 2014

[1]

0653/51/M/J/14

7

www.dynamicpapers.com

Please turn over for Question 3.

© UCLES 2014

0653/51/M/J/14

[Turn over

www.dynamicpapers.com

8
3

You are going to find the density of plasticine (modelling clay).
(a) (i) Mould the piece of plasticine into a shape that approximates to a cube, as shown
in Fig. 3.1.

block of plasticine

h
b
l

Fig. 3.1
Measure the length l, breadth b, and height h, of the cube to the nearest 0.1 cm and
record your results below.
l=

cm

b=

cm

h=

cm

[2]

cm3

[1]

(ii) Calculate the volume, V of your cube by using the equation:
V = l×b×h

V=

© UCLES 2014

0653/51/M/J/14

www.dynamicpapers.com

9

A 50 g mass has been secured to the metre rule. Its position is fixed with its centre over the
10.0 cm mark. Do not attempt to move the mass during the experiment.

x

50 g mass

block of
plasticine

0

metre rule
100
bench

10.0 cm
mark

50.0 cm
mark

knife edge

Fig. 3.2
(b) (i) Place the knife edge directly under the 50.0 cm mark, as shown in Fig. 3.2.
Take the cube of plasticine and place it on the metre rule.
Adjust its position until the rule is just balanced.
Measure, to the nearest 0.1 cm, the distance, x from the centre of the cube to the
50.0 cm mark on the rule.
Record the distance x.
x=

cm

[2]

g

[1]

(ii) Calculate the mass, m of the cube of plasticine using the equation:
m =

2000
x

m=

(iii) Calculate the density, d of the plasticine to an appropriate number of significant figures
using the equation:
d =

m
V

d=

© UCLES 2014

0653/51/M/J/14

g / cm3

[2]

[Turn over

10

www.dynamicpapers.com

(c) Consider the experimental set-up you used for determining the density of plasticine.
Suggest two reasons why the value you have obtained for the density of plasticine may
be inaccurate.
reason 1

reason 2
[2]

© UCLES 2014

0653/51/M/J/14

11
BLANK PAGE

© UCLES 2014

0653/51/M/J/14

www.dynamicpapers.com

12

www.dynamicpapers.com

NOTES FOR USE IN QUALATIVE ANALYSIS
Test for anions
anion

test

test result

carbonate (CO32-)

add dilute acid

effervescence, carbon dioxide
produced

chloride (Cl -)
[in solution]

acidify with dilute nitric acid, then
add aqueous silver nitrate

white ppt.

nitrate (NO3-)
[in solution]

add aqueous sodium hydroxide
then aluminium foil; warm carefully

ammonia produced

sulfate (SO42-)
[in solution]

acidify then add aqueous barium
chloride or aqueous barium nitrate

white ppt.

cation

effect of aqueous sodium hydroxide

effect of aqueous ammonia

ammonium (NH4+)

ammonia produced on warming

-

copper(II) (Cu2+)

light blue ppt., insoluble in excess

light blue ppt., soluble in excess
giving a dark blue solution

iron(II) (Fe2+)

green ppt., insoluble in excess

green ppt., insoluble in excess

iron(III) (Fe3+)

red-brown ppt., insoluble in excess

red-brown ppt., insoluble in excess

zinc (Zn2+)

white ppt., soluble in excess giving
a colourless solution

white ppt., soluble in excess giving
a colourless solution

Test for aqueous cations

Test for gases
gas

test and test results

ammonia (NH3)

turns damp red litmus paper blue

carbon dioxide (CO2)

turns limewater milky

chlorine (Cl2)

bleaches damp litmus paper

hydrogen (H2)

“pops” with a lighted splint

oxygen (O2)

relights a glowing splint

Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
Cambridge International Examinations is part of the Cambridge Assessment Group. Cambridge Assessment is the brand name of University of Cambridge Local
Examinations Syndicate (UCLES), which is itself a department of the University of Cambridge.

© UCLES 2014

0653/51/M/J/14

Advertisement