Physics (0625) · May/June 2025 · CI 53

Cambridge Physics (0625) ci for paper 53, May/June 2025 — 0625/53/M/J/25, file 0625_s25_ci_53.pdf.

Advertisement
Loading the paper…
Text of this paper

Cambridge IGCSE™
PHYSICS

0625/53
May/June 2025

Paper 5 Practical Test
CONFIDENTIAL INSTRUCTIONS
* 9 2 1 3 4 1 3 7 6 0 *

This document gives details of how to prepare for and administer the practical exam.
The information in this document and the identity of any materials supplied by Cambridge International
are confidential and must NOT reach candidates either directly or indirectly.
The supervisor must complete the report at the end of this document and return it with the scripts.
INSTRUCTIONS
●
If you have any queries regarding these confidential instructions, contact Cambridge International
stating the centre number, the syllabus and component number and the nature of the query.
email
[email protected]
phone
+44 1223 553554

This document has 8 pages.
DC (CJ/JG) 342230/1
© UCLES 2025

[Turn over

2

General information about practical exams
Centres must follow the guidance on science practical exams given in the Cambridge Handbook.

Safety
Supervisors must follow national and local regulations relating to safety and first aid.
Only those procedures described in the question paper should be attempted.
Supervisors must inform candidates that materials and apparatus used in the exam should be treated
with caution. Suitable eye protection should be used where necessary.

Before the exam
●
●
●

The packets containing the question papers must not be opened before the exam.
It is assumed that standard school laboratory facilities, as indicated in the Guide to Planning
Practical Science, will be available.
Spare materials and apparatus for the tasks set must be available for candidates, if required.

During the exam
●
●
●
●

It must be made clear to candidates at the start of the exam that they may request spare materials
and apparatus for the tasks set.
Where specified, the supervisor must perform the experiments and record the results as instructed.
This must be done out of sight of the candidates, using the same materials and apparatus as the
candidates.
Any assistance provided to candidates must be recorded in the supervisor’s report.
If any materials or apparatus need to be replaced, for example, in the event of breakage or loss,
this must be recorded in the supervisor’s report.

After the exam
●
●

The supervisor must complete a report for each practical session held and each laboratory used.
Each packet of scripts returned to Cambridge International must contain the following items:
–
the scripts of the candidates specified on the bar code label provided
–
the supervisor’s results relevant to these candidates
–
the supervisor’s reports relevant to these candidates
–
seating plans for each practical session, referring to each candidate by candidate number
–
the attendance register.

© UCLES 2025

0625/53/CI/M/J/25

3

Specific information for this practical exam
During the exam, the supervisor (not the invigilator) must do the experiments in Questions 1, 2
and 3 and record the results on a spare copy of the question paper, clearly labelled ‘supervisor’s
results’.
Question 1
Items to be supplied by the centre (per set of apparatus, unless otherwise specified)
(i)

Metre ruler, graduated in mm, of weight approximately 1 N to 2 N. See note 1.

(ii)

3 × loops of thread or light string. See note 2.

(iii)

2 × force meters, labelled ‘X’ and ‘Y’, each capable of reading forces up to 2.5 N with a
precision of 0.05 N. See note 4.

(iv)

150 g mass, incorporating a hanger and labelled ‘1.50 N load’. This can be formed from a
100 g mass hanger surrounded by modelling clay.

(v)

2 × bosses, 2 × clamps and 2 × stands.

(vi)

Set square.

(vii)

50 cm or 30 cm ruler graduated in mm. Candidates may use their own.

(viii)

Spare loops of thread, as in (ii).

Notes
1

If the metre ruler has two scales in opposite directions, one scale must be taped over.

2

One loop of thread must be looped around the metre ruler so that the 1.50 N load, as in (iv), may
be suspended from it in different positions. The other loops must be fixed (taped) at the 0.0 cm and
100.0 cm marks so that the ruler may be suspended from the force meters as shown in Fig. 1.1.

3

The apparatus must be set up for the candidates as shown in Fig. 1.1, with the metre ruler
suspended with its scale facing upwards. The position of the 1.50 N load on the metre ruler is not
important. However, when the 1.50 N load is suspended at various points between the 10.0 cm
and 90.0 cm marks, the load must be clear of the bench. The force meters and loops of thread
supporting the metre ruler must be vertical. Candidates must be able to move at least one clamp
slightly so that the metre ruler remains horizontal during the experiment.

© UCLES 2025

0625/53/CI/M/J/25

[Turn over

4
clamp
force meter Y

force meter X
stand
metre ruler

0.0 cm mark

100.0 cm mark

1.50 N load

bench

Fig. 1.1
4

The force meters must not exceed their full-scale deflection when the load is suspended at the
10.0 cm or 90.0 cm marks. If they do, force meters capable of reading higher values must be used.
Each force meter scale must be set to zero when the force meters are suspended freely from the
clamps before attaching the ruler.

Action at changeover
Check that the force meters are set to zero as described in note 4.
Check that the apparatus is arranged as shown in Fig. 1.1.
Information required by examiners
A sample set of numerical results, clearly marked ‘supervisor’s results’, obtained out of sight of the
candidates.

Question 2
Items to be supplied by the centre (per set of apparatus, unless otherwise specified)
(i)

250 cm3 beaker. See note 1.

(ii)

Thermometer, –10 °C to 110 °C, graduated in 1 °C intervals.

(iii)

Clamp, boss and stand. See note 2.

(iv)

Supply of hot water. See notes 3 and 4.

(v)

Stop-watch or stop-clock or wall-mounted clock showing seconds. The question will refer to a
stop-watch.

(vi)

Paper towels to soak up any water spills.

Notes
1

If the beaker is not graduated, the 200 cm3 level must be marked on the side of the beaker.

2

The thermometer, clamp, boss and stand are to be set up for candidates as shown in Fig. 2.1. The
thermometer bulb must be well below the 100 cm3 level of the beaker. Candidates must be able
easily and safely to read temperatures up to 100 °C and to move the thermometer into and out of
the beaker.

© UCLES 2025

0625/53/CI/M/J/25

5
thermometer

clamp

beaker

bench

Fig. 2.1
3

Hot water must be available for each candidate throughout the experiment. The hot water must be
maintained at an approximately constant temperature of at least 80 °C. Each candidate will require
about 250 cm3 of hot water in total. Candidates must be able to pour hot water into and out of the
beaker safely.

4

Candidates must be warned of the dangers of burns or scalds when using very hot water.

5

Spare thermometers must be available.

Action at changeover
Empty the water from the beaker.
Check that the apparatus is intact and is arranged as in Fig. 2.1.
Information required by examiners
A sample set of numerical results, clearly marked ‘supervisor’s results’, obtained out of sight of the
candidates.

Question 3
Items to be supplied by the centre (per set of apparatus, unless otherwise specified)
(i)

3 × 2 W, 3 Ω resistors, labelled ‘RP’, ‘R1’ and ‘R2’. Candidates must not be able to detect the
values of the resistors. See note 2.

(ii)

Power supply of approximately 2–3 V. See note 3. Where candidates are provided with a
variable power supply, the voltage should be set by the supervisor and fixed (e.g. taped).

(iii)

Switch. The switch may be an integral part of the power supply.

(iv)

Sufficient connecting leads to set up the circuit shown in Fig. 3.1 plus two spare leads.

(v)

Ammeter capable of measuring currents up to 1.00 A with a precision of at least 0.02 A. See
note 4.

(vi)

Voltmeter capable of measuring the potential difference of the supply with a precision of at
least 0.1 V. See note 4.

© UCLES 2025

0625/53/CI/M/J/25

[Turn over

6
Notes
1

The circuit is to be set up for candidates as shown in Fig. 3.1. Candidates must be able easily
and quickly to disconnect and connect circuit components. The voltmeter must be connected to
terminals labelled ‘P’ and ‘Q’ as shown in Fig. 3.1. The switch must be open.
RP

V
R1

A

P

R2

Q

Fig. 3.1
2

Spare resistors must be available.

3

If cells are used, they must remain adequately charged throughout the examination. Spare cells
must be available.

4

Either analogue or digital meters are suitable. Any variable settings should be set by the supervisor
and fixed (e.g. taped).

Action at changeover
Connect the circuit as shown in Fig. 3.1 and check that the circuit is working.
Open the switch.
Information required by examiners
A sample set of numerical results, clearly marked ‘supervisor’s results’, obtained out of sight of the
candidates.

Question 4
No apparatus is required for this question.

Permission to reproduce items where third-party owned material protected by copyright is included has been sought and cleared where possible. Every
reasonable effort has been made by the publisher (UCLES) to trace copyright holders, but if any items requiring clearance have unwittingly been included, the
publisher will be pleased to make amends at the earliest possible opportunity.
To avoid the issue of disclosure of answer-related information to candidates, all copyright acknowledgements are reproduced online in the Cambridge
Assessment International Education Copyright Acknowledgements Booklet. This is produced for each series of examinations and is freely available to download
at www.cambridgeinternational.org after the live examination series.
Cambridge Assessment International Education is part of Cambridge Assessment. Cambridge Assessment is the brand name of the University of Cambridge
Local Examinations Syndicate (UCLES), which is a department of the University of Cambridge.

© UCLES 2025

0625/53/CI/M/J/25

7

Supervisor’s report
Syllabus and component number

/

Centre number
Centre name
Time of the practical session
Laboratory name/number
Give details of any difficulties experienced by the centre or by candidates (include the relevant
candidate names and candidate numbers).
You must include:
● any difficulties experienced by the centre in the preparation of materials
● any difficulties experienced by candidates, e.g. due to faulty materials or apparatus
● any specific assistance given to candidates.

© UCLES 2025

0625/53/CI/M/J/25

[Turn over

8

Declaration
1 Each packet that I am returning to Cambridge International contains all of the following items:
● the scripts of the candidates specified on the bar code label provided
● the supervisor’s results relevant to these candidates
● the supervisor’s reports relevant to these candidates
● seating plans for each practical session, referring to each candidate by candidate number
● the attendance register.
2 Where the practical exam has taken place in more than one practical session, I have clearly
labelled the supervisor’s results, supervisor’s reports and seating plans with the time and laboratory
name/number for each practical session.
3 I have included details of difficulties relating to each practical session experienced by the centre or
by candidates.
4 I have reported any other adverse circumstances affecting candidates, e.g. illness, bereavement or
temporary injury, directly to Cambridge International on a special consideration form.
Signed (supervisor)
Name (in block capitals)
© UCLES 2025

0625/53/CI/M/J/25