Physics (0625) · May/June 2017 · Mark scheme 62
Cambridge Physics (0625) mark scheme for paper 62, May/June 2017 — 0625/62/M/J/17, file 0625_s17_ms_62.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International Examinations
Cambridge International General Certificate of Secondary Education
PHYSICS
0625/62
Paper 6 Alternative to Practical
May/June 2017
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2017 series for most Cambridge IGCSE®,
Cambridge International A and AS Level and Cambridge Pre-U components, and some Cambridge O Level
components.
® IGCSE is a registered trademark.
This syllabus is approved for use in England, Wales and Northern Ireland as a Cambridge International Level 1/Level 2 Certificate.
This document consists of 6 printed pages.
© UCLES 2017
[Turn over
0625/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
1(a)(i)
May/June 2017
www.dynamicpapers.com
Answer
Marks
V = 0.8 (V)
1
I = 0.65 A both units correct
1
1(a)(ii)
R = 1.2(3) (Ω)
1
1(b)(i)
1.31(Ω) (e.c.f.)
1
1(b)(ii)
length (directly) proportional to resistance/l α R/l = kR
1
1(c)
second box down to be ticked
1
1(d)
different heating effects on wires/wires may be at different temperatures
2
different interpolation of readings between marks on meters/difficult to read the meter (or
ammeter/voltmeter/current/voltage) accurately
difficult to measure length of wire to nearest mm/to judge the position of the sliding contact
cell may run down/power of cell may be less
Any 2 × 1 mark each
Total:
© UCLES 2017
Page 2 of 6
8
0625/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
2(a)
May/June 2017
www.dynamicpapers.com
Answer
Marks
normal in centre of AB at the top face
1
FE at 40° to the left of the normal
1
P1 P2 distance at least 5 cm
1
2(b)
P3 P4 straight line and K correctly marked on CD
1
2(c)
α = 40 ± 2
1
x = 17 ± 2 mm
1
statement is a definite YES or NO, depending on candidate’s measured value of x
1
2(d)
justification to include the idea of within the limits of experimental accuracy/(very)close/almost equal etc. if YES
2(e)
justification to include the idea of outside the limits of experimental accuracy/too far apart/too different etc. if NO
1
any one from:
large pin separation/pins must be >5 cm apart
ensure pins vertical/upright/perpendicular to the paper
view bases of pins
use thin pencil lines/thin pins
1
Total:
© UCLES 2017
Page 3 of 6
9
0625/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
May/June 2017
www.dynamicpapers.com
Answer
Marks
3(a)
50 – 200 cm inclusive
1
3(b)
move (the screen) slowly/carefully back and forth until the best position is found
1
3(c)
9.966/9.97/10 cm
1
answer to 2/3 significant figures (regardless of value – even if incorrect)
1
3(d)
upside down/magnified/fainter/coloured
1
3(e)
A, D, F
3
Total:
© UCLES 2017
Page 4 of 6
8
0625/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
4(a)
May/June 2017
www.dynamicpapers.com
Answer
Marks
graph:
axes correctly labelled
1
suitable scales
1
all plots correct to ½ small square
1
good line judgement, thin, continuous line
1
4(b)
expect NO
line does not pass through origin
1
4(c)
6,40,34
1
consistent units of N cm
1
have not taken the weight of the rule/moment of the weight into account/not realised that Qb + mX = Pa /the pivot is not
at the centre (of mass) of the rule
1
4(d)
Total:
© UCLES 2017
Page 5 of 6
8
0625/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
5
May/June 2017
www.dynamicpapers.com
Answer
Marks
method to include:
MP1
measurements of temperature of hot water over a period of time/measurement of temperature at start and end of a
specified cooling time /measurement of time for a specified temperature drop
1
MP2
repeat using variety of fan speeds (blowing air over water surface)
1
MP3
MP4
two from:
room temperature
initial/starting temperature of hot water
volume/mass/amount of (hot) water
distance of beaker to fan for each speed setting
time of cooling (for a fixed temperature drop)
temperature drop (for a fixed time)
same beaker size/material
2
MP5
table with columns for fan speed, time and temperature with units in the table headings (not the body of the table) for
time and temperature, but fan speed units not required
1
MP6
compare readings to find out which fan speed
produces the greatest temperature drop / takes least time
1
or plot a graph of temperature against time
MP7
in the same time / for same temperature drop
1
or steepest gradient gives the fastest rate of cooling
Total:
© UCLES 2017
Page 6 of 6
7