Chemistry (0620) · Oct/Nov 2018 · Mark scheme 63
Cambridge Chemistry (0620) mark scheme for paper 63, Oct/Nov 2018 — 0620/63/O/N/18, file 0620_w18_ms_63.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge Assessment International Education
Cambridge International General Certificate of Secondary Education
CHEMISTRY
0620/63
Paper 6 Alternative to Practical
October/November 2018
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge International will not enter into discussions about these mark schemes.
Cambridge International is publishing the mark schemes for the October/November 2018 series for most
Cambridge IGCSE™, Cambridge International A and AS Level components and some Cambridge O Level
components.
This syllabus is approved for use in England, Wales and Northern Ireland as a Cambridge International Level 1/Level 2 Certificate.
This document consists of 7 printed pages.
© UCLES 2018
[Turn over
0620/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Generic Marking Principles
October/November 2018
www.dynamicpapers.com
These general marking principles must be applied by all examiners when marking candidate answers. They should be applied alongside the
specific content of the mark scheme or generic level descriptors for a question. Each question paper and mark scheme will also comply with these
marking principles.
GENERIC MARKING PRINCIPLE 1:
Marks must be awarded in line with:
•
•
•
the specific content of the mark scheme or the generic level descriptors for the question
the specific skills defined in the mark scheme or in the generic level descriptors for the question
the standard of response required by a candidate as exemplified by the standardisation scripts.
GENERIC MARKING PRINCIPLE 2:
Marks awarded are always whole marks (not half marks, or other fractions).
GENERIC MARKING PRINCIPLE 3:
Marks must be awarded positively:
•
•
•
•
•
marks are awarded for correct/valid answers, as defined in the mark scheme. However, credit is given for valid answers which go beyond the
scope of the syllabus and mark scheme, referring to your Team Leader as appropriate
marks are awarded when candidates clearly demonstrate what they know and can do
marks are not deducted for errors
marks are not deducted for omissions
answers should only be judged on the quality of spelling, punctuation and grammar when these features are specifically assessed by the
question as indicated by the mark scheme. The meaning, however, should be unambiguous.
GENERIC MARKING PRINCIPLE 4:
Rules must be applied consistently e.g. in situations where candidates have not followed instructions or in the application of generic level
descriptors.
© UCLES 2018
Page 2 of 7
0620/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
October/November 2018
www.dynamicpapers.com
GENERIC MARKING PRINCIPLE 5:
Marks should be awarded using the full range of marks defined in the mark scheme for the question (however; the use of the full mark range may
be limited according to the quality of the candidate responses seen).
GENERIC MARKING PRINCIPLE 6:
Marks awarded are based solely on the requirements as defined in the mark scheme. Marks should not be awarded with grade thresholds or
grade descriptors in mind.
© UCLES 2018
Page 3 of 7
0620/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
1(a)
1(b)
1(c)
1(d)
Answer
Marks
mortar
1
(Teat / dropping) pipette / dropper
1
M1 Limewater
1
M2 milky
1
M1 Larger surface area
1
M2 Increases rate of reaction
1
M1 Add magnesium / zinc / iron
1
M2 More reactive metal / displacement reaction
1
Question
2(a)
October/November 2018
www.dynamicpapers.com
Answer
Table of results for experiments 1–4
Marks
1
average temperature boxes completed correctly
22, 30, 39, 48
2(b)
© UCLES 2018
Time boxes completed correctly
98, 42, 26, 22
2
Times completed in seconds
1
All points plotted correctly
3
Smooth line graph (curve)
1
Page 4 of 7
0620/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
2(c)
Answer
October/November 2018
www.dynamicpapers.com
Marks
indication on graph
1
Value from graph
1
°C
1
2(d)(i)
Experiment 4
1
2(d)(ii)
M1 particles (of solution L) have more / most (kinetic) energy / move faster
1
M2 more frequent collisions / particles collide more often
1
M1 Insulation / use a lid
1
M2 To reduce heat losses
1
M1 Too slow / slower addition of solution
1
M2 Measuring time-taken / results less accurate
1
2(e)
2(f)
Question
Answer
Marks
Tests on solid P
3(a)
White (solid / crystals / powder)
1
3(b)
M1 Bubbles / fizz
1
M2 pH / (red) litmus paper / universal indicator
1
M3 pH>7 / turns blue / alkaline
1
3(c)
No reaction / (remains) colourless / no change
1
3(d)
red
1
© UCLES 2018
Page 5 of 7
0620/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Answer
October/November 2018
www.dynamicpapers.com
Marks
Tests on solid Q
3(e)
© UCLES 2018
•
Transition metal / element
1
•
Chloride / Cl–
1
Page 6 of 7
0620/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
4
Answer
marks may be awarded from labelled diagrams
October/November 2018
www.dynamicpapers.com
Marks
max 6
Ignore any process done to single substances.
If candidates make the mixture up for themselves then carry on marking.
Method 1
1
2
3
4
5
6
7
8
heat the mixture
using a Bunsen / electric heater / oil bath
in a suitable container (flask / boiling tube / test-tube)
ethanol boils / evaporates first / at 78 °C
limonene boils next / at 176 °C (and collects / condenses )
use of the term (fractional) distillation
use of a condenser
sodium carbonate residue left
Method 2 (assuming sodium carbonate does not dissolve
1
2
3
4
5
6
7
8
filter (to obtain sodium carbonate)
heat the filtrate
using a Bunsen / electric heater / oil bath
in a suitable container (flask / boiling tube / test-tube)
ethanol boils / evaporates first / at 78 °C
limonene boils next / at 176 °C (and collects / condenses) / is the residue
use of the term (fractional ) distillation
use of a condenser
Method 3 (assuming sodium carbonate does not dissolve and liquids do not mix).
1
2
3
4
5
© UCLES 2018
max 6
filter (to obtain sodium carbonate)
use of separating funnel
run / let one liquid out
by opening the tap
leave other liquid in separating funnel
Page 7 of 7
max 5