Biology (0610) · Oct/Nov 2019 · Mark scheme 63
Cambridge Biology (0610) mark scheme for paper 63, Oct/Nov 2019 — 0610/63/O/N/19, file 0610_w19_ms_63.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge Assessment International Education
Cambridge International General Certificate of Secondary Education
BIOLOGY
0610/63
Paper 6 Alternative to Practical
October/November 2019
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge International will not enter into discussions about these mark schemes.
Cambridge International is publishing the mark schemes for the October/November 2019 series for most
Cambridge IGCSE™, Cambridge International A and AS Level components and some Cambridge O Level
components.
This syllabus is regulated for use in England, Wales and Northern Ireland as a Cambridge International Level 1/Level 2 Certificate.
This document consists of 8 printed pages.
© UCLES 2019
[Turn over
0610/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
October/November 2019
www.dynamicpapers.com
Generic Marking Principles
These general marking principles must be applied by all examiners when marking candidate answers. They should be applied alongside the specific
content of the mark scheme or generic level descriptors for a question. Each question paper and mark scheme will also comply with these marking
principles.
GENERIC MARKING PRINCIPLE 1:
Marks must be awarded in line with:
•
•
•
the specific content of the mark scheme or the generic level descriptors for the question
the specific skills defined in the mark scheme or in the generic level descriptors for the question
the standard of response required by a candidate as exemplified by the standardisation scripts.
GENERIC MARKING PRINCIPLE 2:
Marks awarded are always whole marks (not half marks, or other fractions).
GENERIC MARKING PRINCIPLE 3:
Marks must be awarded positively:
•
•
•
•
•
marks are awarded for correct/valid answers, as defined in the mark scheme. However, credit is given for valid answers which go beyond the scope
of the syllabus and mark scheme, referring to your Team Leader as appropriate
marks are awarded when candidates clearly demonstrate what they know and can do
marks are not deducted for errors
marks are not deducted for omissions
answers should only be judged on the quality of spelling, punctuation and grammar when these features are specifically assessed by the question
as indicated by the mark scheme. The meaning, however, should be unambiguous.
GENERIC MARKING PRINCIPLE 4:
Rules must be applied consistently e.g. in situations where candidates have not followed instructions or in the application of generic level descriptors.
© UCLES 2019
Page 2 of 8
0610/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
October/November 2019
www.dynamicpapers.com
GENERIC MARKING PRINCIPLE 5:
Marks should be awarded using the full range of marks defined in the mark scheme for the question (however; the use of the full mark range may be
limited according to the quality of the candidate responses seen).
GENERIC MARKING PRINCIPLE 6:
Marks awarded are based solely on the requirements as defined in the mark scheme. Marks should not be awarded with grade thresholds or grade
descriptors in mind.
© UCLES 2019
Page 3 of 8
0610/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Mark scheme
Mark
1(a)(i)
table drawn with lines, minimum two columns + row headings
underlined + suitable headings ;
colour matches condition ;
2
1(a)(ii)
independent variable: light (and dark) / amount of light ;
dependent variable: colour (of the chloroplast suspension) ;
2
1(a)(iii)
volume of chloroplast suspension ;
concentration of chloroplast suspension ;
volume of DCPIP ;
concentration of DCPIP ;
time ;
(same) age / type of leaf ;
temperature / ice-cold ;
buffer solution / pH ;
2
1(a)(iv)
light is needed for photosynthesis / AW ; ora
1
2 and 8 ;
°C ;
2
to identify, anomalous results / outliers / AW ;
1
1(b)
1(c)(i)
© UCLES 2019
Page 4 of 8
October/November 2019
www.dynamicpapers.com
Guidance
0610/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
1(c)(ii)
© UCLES 2019
Mark scheme
error ;
Mark
October/November 2019
www.dynamicpapers.com
Guidance
2 the improvement must match the error given
improvement ;
chloroplasts settle out
stir the chloroplast
suspension
(plastic) pipettes are used to
measure volume / volume of
chloroplasts was inaccurate
use a syringe / burette, to
measure the chloroplasts
temperature not maintained
insulate beaker / use heat
shield / add more ice
DCPIP and chloroplast
extract not mixed
stir or shake
subjective end-point / AW
use colour chart / white
surface / colorimeter
mixture of leaves
select leaves of same type
different time for each testtube
stagger start / do
sequentially
test-tubes not the same
temperature as water-bath
at the start
leave in water-bath for some
time before
starting / equilibrate
AVP, e.g. insufficient CO2
AVP, e.g. add HCO3
Page 5 of 8
0610/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Mark scheme
Mark
1(d)
given method (max 2):
1 method of extracting chloroplasts ;
2 add DCPIP to chloroplasts ;
3 concentration / (stated) volume of chloroplast suspension
;
4 concentration / (stated) volume of DCPIP ;
5 buffer solution / pH ;
new method:
6 two or more different temperatures ;
7 method to maintain temperature ;
8 measure time taken for DCPIP to become
colourless / determine reduction in blue colour after set
time / AW ;
9
equilibrate ;
10 same carbon dioxide / CO2, concentration ;
11 leaves / chloroplasts, from same plant ;
12 same light intensity / same distance from light source ;
13 AVP ;
14 set up a test-tube with no DCPIP to compare to / method
of telling when it has become colourless ;
15 set up control with boiled / no chloroplasts / glass beads ;
16 two or more repeats / replicates ;
17 safety ; e.g. goggles / gloves / ref. to safe method of
heating / ref. to use of tongs for hot objects
© UCLES 2019
Page 6 of 8
October/November 2019
www.dynamicpapers.com
Guidance
6 A correct alternative methods
0610/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Mark scheme
Mark
2 (a)(i)
lines: single clear lines, no shading ;
size: at least half available space ;
detail:
bottom epidermal cell larger than top epidermal cell ;
thickening of guard cell inner cell indicated ;
4
2 (a)(ii)
31 ±1 (mm) ;
0.08 (mm) ;;
3
2 (b)(i)
5 (20% sucrose, repeat 7) circled or indicated ;
1
2 (b)(ii)
3.0 ;
µm ;
2
2(c)(i)
410 ;;
2
2(c)(ii)
axes labelled with units ;
even scale and working area occupies at least half the grid in
both directions + bars clearly identified ;
all values plotted accurately ± half a small square ;
3
2(c)(iii)
(average number of stomata open) decreases and then
increases ;
suitable data quote ; e.g. fewest open at 12:00
/ highest number open at 00:00
/ (decreases) from 0:00 (hours) to 12:00
/ (increases) from 12:00
2
© UCLES 2019
October/November 2019
www.dynamicpapers.com
Guidance
ecf from measurements
Page 7 of 8
0610/63
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Mark scheme
Mark
2(d)(i)
iodine solution ;
1
2(d)(ii)
procedure:
add Benedict’s (solution / reagent) ;
heat ;
green / yellow / orange / (brick) red ;
4
safety:
goggles / gloves / appropriate precaution with hot water
described ;
© UCLES 2019
Page 8 of 8
October/November 2019
www.dynamicpapers.com
Guidance