Biology (0610) · Oct/Nov 2017 · Mark scheme 62
Cambridge Biology (0610) mark scheme for paper 62, Oct/Nov 2017 — 0610/62/O/N/17, file 0610_w17_ms_62.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge Assessment International Education
Cambridge International General Certificate of Secondary Education
BIOLOGY
0610/62
Paper 6 Alternative to Practical
October/November 2017
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge International will not enter into discussions about these mark schemes.
Cambridge International is publishing the mark schemes for the October/November 2017 series for most
®
Cambridge IGCSE , Cambridge International A and AS Level components and some Cambridge O Level
components.
® IGCSE is a registered trademark.
This syllabus is approved for use in England, Wales and Northern Ireland as a Cambridge International Level 1/Level 2 Certificate.
This document consists of 8 printed pages.
© UCLES 2017
[Turn over
0610/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Mark schemes will use these abbreviations
•
•
•
•
•
•
•
•
•
•
•
•
;
/
I
R
A
AW
AVP
ecf
ora
()
underline
max
© UCLES 2017
separates marking points
alternatives
ignore
reject
accept (for answers correctly cued by the question, or guidance for examiners)
alternative wording (where responses vary more than usual)
any valid point
credit a correct statement / calculation that follows a previous wrong response
or reverse argument
the word / phrase in brackets is not required, but sets the context
actual word given must be used by candidate (grammatical variants excepted)
indicates the maximum number of marks that can be given
Page 2 of 8
October/November
www.dynamicpapers.com
2017
0610/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Answer
Marks
1(a)(i)
table drawn with minimum two columns and a line between heading
and data ;
October/November
www.dynamicpapers.com
2017
Guidance
5 R if units in body of table
I units in the body of the table
appropriate column / row headings and appropriate units for
percentage concentration of amylase time for starch to be
digested / minutes ;
three correct amylase concentrations recorded (either order) ;
three correct timings recorded ;
six correct timings recorded ;
1(a)(ii)
1 any one from:
drops (for B at 3, 4 and 5 min) have merged / AW ;
results for C have different end times ;
A at 4 / 5 mins
results for C are different at 3 min ;
no repeats ;
I enzyme will be denatured by high temperature / results
qualitative / subjective / no control / human error
1(a)(iii)
(remove a sample from each of the test-tubes and) add (equal
volume of) Benedict’s solution ;
heat (in a water-bath) ;
© UCLES 2017
Page 3 of 8
2
0610/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
1(b)(i)
Answer
Marks
controlled by
volume / amount of starch
(solution)
5 cm3 / same volume , used
in each
concentration / amount of
starch (solution)
same concentration of starch
solution / used in each
concentration / amount of
iodine
same iodine solution used in
each
volume of enzyme /
amylase
1 cm3 used
temperature
(maintained at) 60°C
time
3 minutes for equilibration
/ testing for, 7 / 8 / 9 / 10,
minutes
I amount of enzyme
I same temperature
;
1(b)(ii)
so the contents of all the test-tubes reach the same temperature
/ AW ;
1
1(b)(iii)
to show that there is no starch in the enzyme solution / amylase
does not react with starch / AW ;
1
© UCLES 2017
Guidance
2 one mark for the variable, one mark for method of
controlling which must related
variable
;
October/November
www.dynamicpapers.com
2017
Page 4 of 8
0610/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
1(c)(i)
Answer
Marks
idea of judging the colour of the endpoint by eye ;
October/November
www.dynamicpapers.com
2017
Guidance
2
idea of doing several procedures at the same time ;
idea of using one drop for both spots of iodine ;
idea that 1 drop for both spots (could cause contamination);
idea of: two samples needed at the same time with the same rod,
(then there will be a difference in the actual time) ;
idea of: size of drops (from either starch or iodine) added varies ;
1(c)(ii)
1 improvement must match one of the errors from 1(c)(i)
e.g. of error
improvement
judging colour by eye
have a standard colour for
comparison / use
colorimeter
timing and sampling at
same time
start timer then mix and
sample and note time when
samples taken / AW
one drop for two samples /
one glass rod
use two rods / pipette
contamination
use two rods / pipette
two samples at the same
time
use two glass rods or do
trials separately
drop size (for either iodine
of drop from glass rod)
use a pipette / syringe
;
© UCLES 2017
Page 5 of 8
0610/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Answer
Marks
October/November
www.dynamicpapers.com
2017
Guidance
1(d)(i)
300 (mg) ;;;
3 if answer incorrect one mark for correct unit and one mark for
correct working:
(3 × 2 × 0.5) ÷ 3 cm3 is max 2
1(d)(ii)
3.4 ;
1 ecf from 1(d)(i)
1(d)(iii)
A(xes) – labelled with units ;
4
S(cale) – even scale ;
P(lot)
– all given points plotted accurately ±½ square ;
L(ines) – each line drawn (with a ruler) point to point / smooth
free-hand curve through points ;
Question
2(a)(i)
Answer
Marks
2 one mark per correct row
feature
epidermis cell
guard cell
shape
wavy outline
oval / bean, shaped
/ AW ;
chloroplasts
/ cell inclusions
absent
present ;
cell wall
thin
thick / thick on inside
edge ;
cell size
large
small ;
cell arrangement
not paired
in pairs ;
© UCLES 2017
Page 6 of 8
Guidance
0610/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
2(a)(ii)
Answer
Marks
outline single clear continuous lines, no shading, 2 cells drawn ;
October/November
www.dynamicpapers.com
2017
Guidance
4
drawing occupies at least 50 mm along X–Y ;
stoma width is about one sixth of total width of XY ;
cell walls drawn as double line not too wide ;
2(b)
(diameter of guard cells and stomata) value within the range of
31–34 mm ;
3
line drawn on candidates diagram and measurement ±1 mm;
calculated magnification ;
2(c)
absorption (rate) is lower than transpiration 09:00 to 18:00 / during
the day / during the light ora ;
absorption (rate) is higher than transpiration from 18:00 to 06:00 / at
night / in the dark ora ;
absorption peaks at 18.00 and transpiration peaks between 14:00
to16:00 / absorption rate peaks after transpiration rate ora ;
transpiration rate increases faster than absorption rate ;
comparative data quote for both curves ;
rate of absorption and rate transpiration are equal between 08:00 to
09:00 / at 18:00 ;
© UCLES 2017
Page 7 of 8
2 A times in am and pm equivalents
A some variation in the 09:00 time
0610/62
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
2(d)
Answer
Marks
1
ref. to using at least 3 temperatures / humidity ;
2
ref. to (three) values for temperature / humidity ;
3
ref. to means of obtaining the different temperatures / humidity;
4
ref. to checking that the apparatus does not leak ;
5
ref. to one controlled variable ;
6
ref. to second controlled variable;
7
ref. to measuring distance moved (by the air) along capillary ;
8
ref. to fixed time / timing for a fixed distance ;
9
ref. to refilling capillary between measurements ;
Guidance
6
A high, medium and low for humidity and temperature
e.g. for mp 5 and mp 6: light intensity, light wavelength, wind
speed, temperature or humidity
10 ref. to at least two replicates ;
11 use same shoot / same number of leaves / same area of
leaves ;
12 AVP ; e.g. detail of apparatus set up e.g. cutting shoot
underwater / drying leaves allow apparatus to equilibrate before
taking any readings
© UCLES 2017
October/November
www.dynamicpapers.com
2017
Page 8 of 8