Biology (0610) · Oct/Nov 2013 · Mark scheme 63

Cambridge Biology (0610) mark scheme for paper 63, Oct/Nov 2013 — 0610/63/O/N/13, file 0610_w13_ms_63.pdf.

Advertisement
Loading the paper…
Text of this paper

www.dynamicpapers.com

CAMBRIDGE INTERNATIONAL EXAMINATIONS
International General Certificate of Secondary Education

MARK SCHEME for the October/November 2013 series

0610 BIOLOGY
0610/63

Paper 6 (Alternative to Practical), maximum raw mark 40

This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of
the examination. It shows the basis on which Examiners were instructed to award marks. It does not
indicate the details of the discussions that took place at an Examiners’ meeting before marking began,
which would have considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner
Report for Teachers.

Cambridge will not enter into discussions about these mark schemes.

Cambridge is publishing the mark schemes for the October/November 2013 series for most IGCSE,
GCE Advanced Level and Advanced Subsidiary Level components and some Ordinary Level
components.

www.dynamicpapers.com
Page 2

Mark Scheme
IGCSE – October/November 2013

Syllabus
0610

Paper
63

Mark schemes will use these abbreviations:
;
/
R
A
I
ecf
AW
AVP
underline
()
D, L, T, Q
max

separates marking points
alternatives
reject
accept (for answers correctly cued by the question)
ignore as irrelevant
error carried forward
alternative wording (where responses vary more than usual)
alternative valid point
actual word given must be used by candidate (grammatical variants excepted)
the word / phrase in brackets is not required but sets the context
quality of: drawing / labelling / table / detail as indicated
indicates the maximum number of marks

© Cambridge International Examinations 2013

www.dynamicpapers.com
Page 3

Question

Answer

1

drawing: O – outline;

(a) (i)

Mark Scheme
IGCSE – October/November 2013

Syllabus
0610
Marks

Paper
63

Guidance for Examiners
clear, unbroken lines with no shading
larger than original

S – size;
D – detail;
L – label;
one label from: seed(s) / (remains of) stigma or
style / stem or stalk or pedicel / succulent part or
flesh or cortex
(ii)

label line must end on structure, even if
unambiguous
[4]
A. 87–90 mm

length of X – X of Fig.1.1;
equivalent length X – X of drawing;
formula;
length X – X on drawing ÷ length X – X on Fig.1.1.

(b) (i)

mark is independent of other marking points

answer;

[4]

skin / seed(s) / stalk or stem / both have flesh AW / smooth
surface / skin;

[1]

© Cambridge International Examinations 2013

www.dynamicpapers.com
Page 4

(ii)

(c)

Mark Scheme
IGCSE – October/November 2013

difference

apple

plum

stem

un-branched
straight
smooth
AW

branched;
crooked;
uneven surface;
AW

seeds

darker
2 visible / 1+
at two sides
smaller
AW

lighter
one;
central;
larger;
AW

fleshy part

thick(er)
light / white

thin(er);
dark;

size of whole
fruit

larger / larger SA
unequal halves
basal indentation

smaller/smaller SA;
symmetrical;
absent;

Syllabus
0610

Paper
63

any three differences in one box or row could gain
3 marks, but inconsistencies negate
features must be visible, not inferred
no mark for naming the feature, but must be clearly
stated

[max. 3]

safety feature;
Benedict’s solution;

A fehling’s / copper sulphate + sodium hydroxide or
potassium hydroxide
A clinistix

heat / boil / 70 °C+ cited;

I warm

colour change blue / turquoise to green / yellow / orange / red ;

[4]
[Total: 16]

© Cambridge International Examinations 2013

initial colour must be given

www.dynamicpapers.com
Page 5

2

(a)

Mark Scheme
IGCSE – October/November 2013

Syllabus
0610

Paper
63

A – axes label + even scale;
spacing of numerical values used in plots to fill half
the grid or more in both directions

S – size;
P – plot:
time / s
pH

40 °C

50 °C

5.5

600

850

6.0

360

500

7.0

50

70

7.5

35

65

8.0

45

100
ruler drawn point to point / smooth curve

L – line;
K – key;
(b) (i)

[5]

describe:
increased rate / decreased time as pH increases (5.5–7.5);
pH 7.5 identified as optimum / most rapid / least time taken;
decreased rate / increased time as pH increases (7.5 to 8.0);
explain:
(enzyme activity changes because) enzyme is denatured /
shape of active site is altered AW;

[4]

© Cambridge International Examinations 2013

www.dynamicpapers.com
Page 6

(ii)

Mark Scheme
IGCSE – October/November 2013

Syllabus
0610

Paper
63

describe:
takes more time / slower at 50˚C / ORA for 400C;
difference more marked at pH 5.5 and pH 8.0 AW;
similar shape to curves / AW;
data comparison;

(c) (i)
(ii)

[max. 2]

to come to same temperature / equilibrate;

[1]

mark ‘X’ or similar mark on underside / waterproof mark / AW;
hold against dark background / AW
comparison with distilled water and undigested milk or with end
point / AW;
shine a light through / use of a meter;

(d) (i)
(ii)

[max. 1]

at least three other temperatures in addition to 40°C + 50°C;

[1]
any three from any line

pH;
trypsin: conc; volume / amount; type;
milk: conc; volume / amount; substrate;

max [2]

(iii)

time to clear / AW;

[1]

(iv)

water / boiled enzyme / inactive enzyme;

[1]
[Total: 18]

© Cambridge International Examinations 2013

www.dynamicpapers.com
Page 7

3

(a)

Mark Scheme
IGCSE – October/November 2013

Syllabus
0610

Paper
63

carbon dioxide – 0.04% / lower and 4.0% / higher;
water – varies due to humidity of surroundings / AW and more /
saturated;

(b) (i)

[2]

test – limewater ;
results – clear / colourless / transparent to cloudy;
[2]

(ii)

test – (anhydrous) copper sulphate / cobalt chloride;
results – white to blue for copper sulphate
blue to pink for cobalt chloride;

[2]
[Total: 6]

© Cambridge International Examinations 2013

A. hydrogen carbonate solution – red to yellow.
initial colour must be given

Advertisement