Biology (0610) · May/June 2017 · Mark scheme 61
Cambridge Biology (0610) mark scheme for paper 61, May/June 2017 — 0610/61/M/J/17, file 0610_s17_ms_61.pdf.
Text of this paper
www.dynamicpapers.com
Cambridge International Examinations
Cambridge International General Certificate of Secondary Education
BIOLOGY
0610/61
Paper 6 Alternative to Practical
May/June 2017
MARK SCHEME
Maximum Mark: 40
Published
This mark scheme is published as an aid to teachers and candidates, to indicate the requirements of the
examination. It shows the basis on which Examiners were instructed to award marks. It does not indicate the
details of the discussions that took place at an Examiners’ meeting before marking began, which would have
considered the acceptability of alternative answers.
Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for
Teachers.
Cambridge will not enter into discussions about these mark schemes.
Cambridge is publishing the mark schemes for the May/June 2017 series for most Cambridge IGCSE®,
Cambridge International A and AS Level and Cambridge Pre-U components, and some Cambridge O Level
components.
® IGCSE is a registered trademark.
This document consists of 9 printed pages.
© UCLES 2017
[Turn over
0610/61
Cambridge IGCSE – Mark Scheme
PUBLISHED
Mark schemes will use these abbreviations
•
•
•
•
•
•
•
•
•
•
•
•
;
/
I
R
A
AW
AVP
ecf
ora
()
underline
max
© UCLES 2017
separates marking points
alternatives
ignore
reject
accept (for answers correctly cued by the question, or guidance for examiners)
alternative wording (where responses vary more than usual)
any valid point
credit a correct statement / calculation that follows a previous wrong response
or reverse argument
the word / phrase in brackets is not required, but sets the context
actual word given must be used by candidate (grammatical variants excepted)
indicates the maximum number of marks that can be given
Page 2 of 9
May/June 2017
www.dynamicpapers.com
0610/61
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
1(a)(i)
Answer
Marks
(tube 3) = 0.10 ;
May/June 2017
www.dynamicpapers.com
Guidance
2
(tube 7) = 0.80 ;
1(a)(ii)
purple / violet / lilac / mauve / AW ;
1
1(a)(iii)
(shows a sequence)
1=+
2 and 3 = ++
4 = +++
5 and 6 = ++++ ;
1
1(a)(iv)
table drawn with 14 cells for results and 2 heading cells ;
3
R % symbol in body of table
column and row headings and
appropriate units for each heading ;
recording of any concentrations and the intensity scores
from (a)(iii) ;
1(a)(v)
records ++ or +++ for tube A
and, ++++ for tube B ;
1
1(a)(vi)
tube A between 0.05% to 0.20% (inclusive) / figure quoted
from range ;
2 ecf from (a)(iii) and (a)(v)
tube B between 0.40% (inclusive) to whatever given in their
table (or figure quoted from range) ;
1(b)(i)
tube 1 / tube with only water / tube with no protein / 0%
protein ;
to show effect due to protein / for comparison of colour with
tubes containing protein / to show colour when no protein is
present / AW ;
© UCLES 2017
Page 3 of 9
2
0610/61
Question
1(b)(ii)
Cambridge IGCSE – Mark Scheme
PUBLISHED
Answer
Marks
idea that it is a qualitative method / not quantitative / not
measured ;
subjective / judged by eye / could be visually impaired ;
similar concentrations look the same / not enough intervals
to be precise ;
© UCLES 2017
Page 4 of 9
2
May/June 2017
www.dynamicpapers.com
Guidance
0610/61
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Answer
Marks
May/June 2017
www.dynamicpapers.com
Guidance
2(a)(i)
any two correct labels to different structures on Fig. 2.1 ;
1
2(a)(ii)
marks on 4 cells or 3 and PQ on Fig.2.1 and 4
measurements with units ;
2 ecf for average if no units given
average correct from candidates measurements with units ;
2(a)(iii)
(cell A) 12 ± 1mm ;
3
ecf incorrect measurement of cell A
if answer incorrect, award 1 mark for correct working shown
(12 ÷ 800)
(actual length) 0.015 mm ;;
2(a)(iv)
single clear continuous lines with no
shading / stippling / hatching ;
4
drawing occupies at least half of the space provided ;
detail marks
one entire cell and one budding cell with correct
proportions and orientation and angles ;
circular or rounded inclusions shown (minimum of one
in entire cell, one in mother cell and two in the bud) ;
© UCLES 2017
Page 5 of 9
0610/61
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
2(b)(i)
Answer
Marks
time qualified e.g. time intervals for measurements / total
time of measuring ;
temperature ;
(starting) volume of yeast ;
same yeast culture ;
© UCLES 2017
Page 6 of 9
2
May/June 2017
www.dynamicpapers.com
Guidance
0610/61
Question
2(b)(ii)
Cambridge IGCSE – Mark Scheme
PUBLISHED
Answer
Marks
error:
loss of yeast from syringe (so less respiration / gas
released) ;
improvement:
idea of: sealed syringe / 3-way tap and collecting gas
using gas syringe / AW ;
error:
idea of taking up, air / froth, with the yeast ;
improvement:
filling from below the level of the foam ;
error:
samples of yeast may vary in concentration ;
improvement:
mix / stir, the culture before removing samples ;
error:
no method of maintaining temperature ;
improvement:
use a thermostatically controlled water bath / Bunsen
burner and thermometer / idea of insulation ;
error:
syringe containing yeast not equilibrated before using ;
improvement:
idea of leaving for a time to reach, correct
temperature / 35 °C ;
error:
syringe has an imprecise scale ;
improvement:
use a syringe with more graduations ;
© UCLES 2017
Page 7 of 9
May/June 2017
www.dynamicpapers.com
Guidance
2 improvement must relate to the error given
0610/61
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
Answer
Marks
2(c)(i)
13.5(0) ;
1
2(c)(ii)
axes labelled with units ;
4
even scale and plots to fill half or more of the printed grid on
both axes ;
points plotted accurately ±½ square ;
line ;
2(c)(iii)
© UCLES 2017
there is large difference between syringe 1 and 2 / AW ;
Page 8 of 9
1
May/June 2017
www.dynamicpapers.com
Guidance
0610/61
Cambridge IGCSE – Mark Scheme
PUBLISHED
Question
2(d)
Answer
1
using 20 cm3 of yeast culture ;
2
using a water bath at, same temperature / 35°C ;
3
measuring volume of gas every 5 minutes ;
4
total time for gas collection 25 minutes ;
5
use of at least 3 different pH values ;
6
stated range of values ;
7
same volumes of pH solutions added ;
8
ref to method of measuring the pH values used ;
9
adding the pH solution to the yeast culture ;
Marks
Guidance
6 max 2 from MP1-4 (the given method)
10 repeats – use of (at least) 3 (syringes) per pH tested ;
11 measuring gas produced by a new method
e.g. use of gas syringe / time how long it takes for each
syringe to produce a certain volume of gas ;
12 method of maintaining water-bath at a constant
temperature ;
13 relevant safety precaution ;
© UCLES 2017
May/June 2017
www.dynamicpapers.com
Page 9 of 9